Douglas County/Highlands Ranch Colorado Roofing Codes
These are the current roofing codes for Douglas County and Highlands Ranch Colorado. The minimum sustained wind speed rating for asphalt shingles varies by elevation, specifically if the property is above 7000 feet.
Information Updated On
9/23/18
Building Department Phone
303-660-7497
Inspection Line
303-660-7497 option #1
Current Building Code
2012 IBC/IRC
Current Energy Code
2012 IECC
Requires a Building Permit
Yes
Other/Special Permits required
Sheathing
Roof System/Fire Rating required for Residential Dwellings
Class C
Roof System/Fire Rating required for Commercial Buildings
Class C
Roof System/Fire Rating required for Multi-Family
Class C
Special conditions
Class of roof system is dependent on type of construction
Minimum sustained wind speed rating for Asphalt Shingles
If over 7000 feet, sustained wind shall be 120 MPH
ASTM Standard for wind rating;
D 7158
Requires a manufacturer’s wind warranty
Per manufacturer 90/120
Requires wind nailing
Yes, if above 7000 ft
Inspectors carry ladders for the final
No, inspectors do not carry ladders
Requires final inspection
Yes
Requires mid-roof inspection
For batten roofing systems only
Maximum number of layers of flat roof material permitted
One unless approved by manufacturer
Require a sheathing/decking inspection
No
Requires solid sheeting (plywood/OSB) over spaced decking
Yes
Maximum gap size for sheeting
Any gap at all – asphalt shingles shall not be installed over spaced decking
Requires drip edge
Yes
Drip edge size minimum
4 x 2
Requires Rake/Gable metal edging
Yes
Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)
No
Underlayment required for 4:12 and above
15# asphalt shingle
Type of valleys allowed
Open and closed
Valley Underlayment/Material required for closed valleys
Either – 90# or metal is also ok for asphalt shingle
Valley Underlayment/Material required for open valleys
Either – 90# is also ok
Kick-out required on Step Flashing
Yes
Minimum curb height requirement
Yes
Chimney crickets requirement
Any area 30” or more on a roof surface causing a water dam; ie. Skylights, swamp coolers.
Requires ridge cap
Yes
Requires ventilation to meet building codes
Yes
Requires blower door test when increasing ventilation to code
Yes
Requires Soffit eave/vents
Yes
Low Slope
1:12
Was delighted to have quality work done in a timely manner. Especially considering the demand in the construction industry right now where sometimes even getting a call back seems like an oddity. Will return for future roofing needs.Dana Hubbard2021-03-10Pete was vert professional and easy to communicate. Made it easy for us and I recommend them to all future customers.Jandos Yerkhanat2021-03-04I am very satisfied with their work and their work ethic. Job was done in a timely fashion. Customer service was not lacking, every time I would call I would get an immediate response. They went beyond the usual for me and I would recommend them highly!! Thank you Peak to Peak Roofing!!Grace Barbera2021-02-05My realtor suggested Damen at Peak to Peak for a roof replacement through our insurance. We were on a timeline to sell our home, and Damen was an absolute rock star. He answered the call on a Sunday night, showed up for an inspection and helped us through the process - getting the entire job done within a couple short weeks. The roof looks amazing, and Damen also met with our insurance adjuster and added the gutters and garage door. I can't say enough about the professionalism, communication, availability and work that Damen and Peak to Peak provide. Give them a call - you won't regret it!Chase Piker2021-02-01Peak to Peak Roofing did a great job on putting new nsulation in my attic. Never left a mess. Would recommend them to anyone who needs this type of workDaryl Otwell2021-01-26They were very helpful in getting repair done in a timely manner. They also painted the house. Everything looks very good and well done.Joan Costa2021-01-25