Edgewater Colorado Roofing Codes
The Edgewater Colorado roofing codes are based on 2009 building codes and 2009 energy codes. Ventilation is required to meet the building codes.
Information Updated On
6-3-2018
Building Department Phone
720-763-3001
Inspection Line
303-450-8748
Current Building Code
2009 IBC/IRC
Current Energy Code
2009 IECC
Roof System/Fire Rating required for Residential Dwellings
Class A
Roof System/Fire Rating required for Commercial Buildings
Class A
Roof System/Fire Rating required for Multi-Family
Class A
ASTM Standard for wind rating
D 3161
Inspectors carry ladders for the final
No
Requires midroof (in progress) inspection
Yes, at 25% complete
Requires solid sheeting (plywood/OSB) over spaced decking
Yes
Minimum gap size for sheeting
To manufacturer specs
Requires drip edge
Yes
Drip edge size minimum
1 x 2
Requires Rake/Gable metal edging
Yes
Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)
Yes
Underlayment required for 4:12 and above
15#
Type of valleys allowed
Closed only
Valley Underlayment/Material required for closed valleys
Ice and water shield
Requires ventilation to meet building codes
Yes