Clear Creek County Roofing Codes: Permits, Inspections, and Requirements

Adopted building and energy codes, permit rules, and roofing requirements for Clear Creek County, Clear Creek County. Rows below reflect our reading of the jurisdiction's own published sources, linked at the bottom of the page.

Last checked Compiled from published Clear Creek County and city pages

Clear Creek County roofing code requirements

Clear Creek County roofing code reference
Current building code
What this jurisdiction requires
2024 IBC and 2024 IRC
Current energy code
What this jurisdiction requires
2024 IECC
Building permit required
What this jurisdiction requires
Yes
Roof system fire rating (residential)
What this jurisdiction requires
Class A required under the 2025 Colorado Wildfire Resiliency Code
Roof system fire rating (commercial)
What this jurisdiction requires
Class A
Roof system fire rating (multi-family)
What this jurisdiction requires
Class A
Minimum wind speed rating for asphalt shingles
What this jurisdiction requires
100 MPH
Requires wind nailing
What this jurisdiction requires
Yes
Inspectors carry ladders for the final
What this jurisdiction requires
No
Requires midroof (in progress) inspection
What this jurisdiction requires
Yes, required at the point that drip edge, flashing, underlayment, and ice barrier have been installed.
Requires a sheathing / decking inspection
What this jurisdiction requires
Yes, if decking is being replaced
Maximum layers of asphalt shingles permitted
What this jurisdiction requires
Only 1 layer permitted
Maximum layers of flat roof material permitted
What this jurisdiction requires
Only one layer permitted
Requires solid sheeting over spaced decking
What this jurisdiction requires
Yes
Sheeting gap requirement
What this jurisdiction requires
¼" gap
Requires drip edge
What this jurisdiction requires
Yes
Minimum drip edge size
What this jurisdiction requires
2 x 2
Requires rake / gable metal edging
What this jurisdiction requires
Yes
Self adhering underlayment (ice and water shield)
What this jurisdiction requires
Ice barrier required at eaves per IRC R905.1.2
Underlayment required 2:12 up to 4:12
What this jurisdiction requires
19" overlap of 30 pound
Underlayment required 4:12 and above
What this jurisdiction requires
15 pound self adhering at eave 2' from exterior wall line
Type of valleys allowed
What this jurisdiction requires
Open and Closed
Valley material required for closed valleys
What this jurisdiction requires
Ice and water shield
Valley material required for open valleys
What this jurisdiction requires
Ice and water shield
Kick-out required on step flashing
What this jurisdiction requires
Yes
Chimney cricket requirement
What this jurisdiction requires
30" or greater width
Requires ridge cap
What this jurisdiction requires
Yes
Requires ventilation to meet code
What this jurisdiction requires
Yes
Requires soffit / eave vents
What this jurisdiction requires
Yes, new construction only

Last checked September 2, 2026. This reflects published sources at that date, not an official ruling. Code adoptions change, so confirm with the Clear Creek County building department before you pull a permit.

What Clear Creek County requires, in plain language

Clear Creek County builds to the 2024 IBC and 2024 IRC. That edition, not the newest code published nationally, is the rulebook an inspector in Clear Creek County holds your roof to. Energy work on the same permit follows the 2024 IECC.

Layer limit in Clear Creek County: Only 1 layer permitted. This is the line item that moves a bid the most. If your existing roof is already at the limit, the deck gets stripped before new material goes down, and the labor plus dump fees belong in the written price. Flat roof sections are capped at Only one layer permitted.

Wind is what Clear Creek County tests shingles against. Shingles need a 100 MPH rating. Wind nailing: Yes.

Underlayment and edge metal are where roofs fail inspection. Ice and water shield: Ice barrier required at eaves per IRC R905.1.2. On 2:12 to 4:12 slopes: 19" overlap of 30 pound. On 4:12 and steeper: 15 pound self adhering at eave 2' from exterior wall line. Drip edge: Yes. Minimum drip edge size 2 x 2.

Clear Creek County adopted the 2024 International Residential, Building, Plumbing, Mechanical, Fuel Gas, Energy Conservation and Swimming Pool codes by resolution, along with the 2025 Colorado Wildfire Resiliency Code.

Installation details above come from our building department field survey for Clear Creek County, last updated 9/16/18. Code editions and contacts are refreshed from the department directly. Always confirm the details on your permit before work starts, since departments amend requirements on their own schedule.