Longmont Roofing Codes: Permits, Inspections, and Requirements
Adopted building and energy codes, permit rules, and roofing requirements for Longmont, Boulder County. Rows below reflect our reading of the jurisdiction's own published sources, linked at the bottom of the page.
Building department
303-651-8332Inspection line
303-651-8336Permit line
303-651-8332Official department
Live code pageLongmont roofing code requirements
- What this jurisdiction requires
- 2024 IBC and 2024 IRC
- What this jurisdiction requires
- Metro Cohort Model Code, based on the 2024 IECC
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Yes, late 2018
- What this jurisdiction requires
- 110 MPH sustained wind/130 MPH 3 second gusts
- What this jurisdiction requires
- ASTM D3161 Class F, D7158 Class G & H
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Yes, with one story access
- What this jurisdiction requires
- Yes, for commercial before dry-in
- What this jurisdiction requires
- Only 1 layer is permitted
- What this jurisdiction requires
- Only 1 layer permitted
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- 2 x 3
- What this jurisdiction requires
- No
- What this jurisdiction requires
- No
- What this jurisdiction requires
- A double layer of underlayment required
- What this jurisdiction requires
- One layer of minimum Type 15 required
- What this jurisdiction requires
- Both
- What this jurisdiction requires
- Either
- What this jurisdiction requires
- Either
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Yes
| Requirement | What this jurisdiction requires |
|---|---|
| Current building code | 2024 IBC and 2024 IRC |
| Current energy code | Metro Cohort Model Code, based on the 2024 IECC |
| Building permit required | Yes |
| Plans to update the code | Yes, late 2018 |
| Minimum wind speed rating for asphalt shingles | 110 MPH sustained wind/130 MPH 3 second gusts |
| ASTM standard for wind rating | ASTM D3161 Class F, D7158 Class G & H |
| Requires a manufacturer wind warranty | Yes |
| Inspectors carry ladders for the final | Yes, with one story access |
| Requires midroof (in progress) inspection | Yes, for commercial before dry-in |
| Maximum layers of asphalt shingles permitted | Only 1 layer is permitted |
| Maximum layers of flat roof material permitted | Only 1 layer permitted |
| Requires solid sheeting over spaced decking | Yes |
| Requires drip edge | Yes |
| Minimum drip edge size | 2 x 3 |
| Requires rake / gable metal edging | No |
| Self adhering underlayment (ice and water shield) | No |
| Underlayment required 2:12 up to 4:12 | A double layer of underlayment required |
| Underlayment required 4:12 and above | One layer of minimum Type 15 required |
| Type of valleys allowed | Both |
| Valley material required for closed valleys | Either |
| Valley material required for open valleys | Either |
| Kick-out required on step flashing | Yes |
| Requires ventilation to meet code | Yes |
Last checked September 2, 2026. This reflects published sources at that date, not an official ruling. Code adoptions change, so confirm with the Longmont building department before you pull a permit.
What Longmont requires, in plain language
Longmont builds to the 2024 IBC and 2024 IRC. That edition, not the newest code published nationally, is the rulebook an inspector in Boulder County holds your roof to. Energy work on the same permit follows the Metro Cohort Model Code, based on the 2024 IECC. Update status: Yes, late 2018
Layer limit in Longmont: Only 1 layer is permitted. This is the line item that moves a bid the most. If your existing roof is already at the limit, the deck gets stripped before new material goes down, and the labor plus dump fees belong in the written price. Flat roof sections are capped at Only 1 layer permitted.
Wind is what Longmont tests shingles against. Shingles need a 110 MPH sustained wind/130 MPH 3 second gusts rating. Rating is proven under ASTM D3161 Class F, D7158 Class G & H. Manufacturer wind warranty: Yes.
Underlayment and edge metal are where roofs fail inspection. Ice and water shield: No. On 2:12 to 4:12 slopes: A double layer of underlayment required. On 4:12 and steeper: One layer of minimum Type 15 required. Drip edge: Yes. Minimum drip edge size 2 x 3.
Longmont has adopted the 2024 International Codes, the Metro Cohort Model Code, and the Colorado Wildfire Resiliency Code, effective July 1, 2026.
Installation details above come from our building department field survey for Longmont, last updated 8/22/18. Code editions and contacts are refreshed from the department directly. Always confirm the details on your permit before work starts, since departments amend requirements on their own schedule.

Sources
These links go straight to the jurisdiction, so you always have the real-time source. Adoptions and amendments change on their schedule, not ours. Always confirm before permitting.
Keep going
Nearby jurisdictions
Last checked September 2, 2026. This is our best read of published sources, not an official ruling. Confirm with the Longmont building department before you pull a permit.