Centennial Colorado Roofing Codes
These are the specs for the City of Centennial Colorado roofing codes. Note there is a requirement for midroof inspections, and there is a minimum asphalt saturated underlayment requirement.
Information Updated On
8/22/18
Building Department Phone
303-754-3321
Inspection Line
303-754-3321
Fax Line
303-708-1790
Current Building Code
2015 IRC/IBC
Current Energy Code
2015 IECC
Requires a Building Permit
Yes
Roof System/Fire Rating required for Residential Dwellings
Class A
Minimum sustained wind speed rating for Asphalt Shingles
90 MPH Sustained/110 MPH 3-second gusts
Requires wind nailing
Yes
Inspectors carry ladders for the final
Yes, with one story access
Requires midroof (in progress) inspection
Yes, inspection required at 25% to 75% shingled for concrete, tile, and shake shingle, metal, and flat roofs.
Maximum number of layers of asphalt shingles permitted
Single layer only
Maximum number of layers of flat roof material permitted
Single layer only
Require a sheathing/decking inspection
No
Requires solid sheeting (plywood/OSB) over spaced decking
Yes
Minimum gap size for sheeting
½ inch gap
Requires drip edge
No
Requires Rake/Gable metal edging
No
Enforces the use of Self Adhering Underlayment (i.e., Ice & Water)
No
Underlayment required 2:12 up to 4:12
Minimum 15-pound asphalt saturated underlayment required. 19-inch laps of underlayment are required, starting with a 19-inch strip and then full sheets.
Underlayment required for 4:12 and above
One layer of 15-pound (minimum) asphalt saturated underlayment required.
Type of valleys allowed
Both
Valley Underlayment/Material required for closed valleys
90 pound
Valley Underlayment/Material required for open valleys
Ice and water under metal
Kick-out required on Step Flashing
Yes
Minimum curb height requirement
No
Chimney crickets requirement
30 inch or greater width
Requires ridge cap
Yes
Requires ventilation to meet building codes
Yes
Requires blower door test when increasing ventilation to code
No
Requires Soffit eave/vents
No
Allows 90 lb rolled roofing on low slope heating living space
Yes
Slope
2:12
Was delighted to have quality work done in a timely manner. Especially considering the demand in the construction industry right now where sometimes even getting a call back seems like an oddity. Will return for future roofing needs.Dana Hubbard2021-03-10Pete was vert professional and easy to communicate. Made it easy for us and I recommend them to all future customers.Jandos Yerkhanat2021-03-04I am very satisfied with their work and their work ethic. Job was done in a timely fashion. Customer service was not lacking, every time I would call I would get an immediate response. They went beyond the usual for me and I would recommend them highly!! Thank you Peak to Peak Roofing!!Grace Barbera2021-02-05My realtor suggested Damen at Peak to Peak for a roof replacement through our insurance. We were on a timeline to sell our home, and Damen was an absolute rock star. He answered the call on a Sunday night, showed up for an inspection and helped us through the process - getting the entire job done within a couple short weeks. The roof looks amazing, and Damen also met with our insurance adjuster and added the gutters and garage door. I can't say enough about the professionalism, communication, availability and work that Damen and Peak to Peak provide. Give them a call - you won't regret it!Chase Piker2021-02-01Peak to Peak Roofing did a great job on putting new nsulation in my attic. Never left a mess. Would recommend them to anyone who needs this type of workDaryl Otwell2021-01-26They were very helpful in getting repair done in a timely manner. They also painted the house. Everything looks very good and well done.Joan Costa2021-01-25