Englewood Roofing Codes: Permits, Inspections, and Requirements
Adopted building and energy codes, permit rules, and roofing requirements for Englewood, Arapahoe County. Rows below reflect our reading of the jurisdiction's own published sources, linked at the bottom of the page.
Building department
303-762-2356Inspection line
303-762-2356Permit line
303-762-2356Official department
Live code pageEnglewood roofing code requirements
- What this jurisdiction requires
- 2021 IBC and 2021 IRC
- What this jurisdiction requires
- 2021 IECC
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Class A
- What this jurisdiction requires
- D-3161
- What this jurisdiction requires
- Yes, with one story access
- What this jurisdiction requires
- One layer
- What this jurisdiction requires
- One layer
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Required
- What this jurisdiction requires
- 1 x 2
- What this jurisdiction requires
- Required
- What this jurisdiction requires
- Ice barrier required at eaves per the IRC
- What this jurisdiction requires
- Two layers of underlayment
- What this jurisdiction requires
- One layer of underlayment
- What this jurisdiction requires
- Both
- What this jurisdiction requires
- Required where the roof meets a wall
- What this jurisdiction requires
- Required, installed to manufacturer specifications
- What this jurisdiction requires
- Yes, per code
- What this jurisdiction requires
- Required on new construction under the 2021 IECC
- What this jurisdiction requires
- Required per IRC attic ventilation provisions
| Requirement | What this jurisdiction requires |
|---|---|
| Current building code | 2021 IBC and 2021 IRC |
| Current energy code | 2021 IECC |
| Building permit required | Yes |
| Roof system fire rating (residential) | Class A |
| ASTM standard for wind rating | D-3161 |
| Inspectors carry ladders for the final | Yes, with one story access |
| Maximum layers of asphalt shingles permitted | One layer |
| Maximum layers of flat roof material permitted | One layer |
| Requires solid sheeting over spaced decking | Yes |
| Requires drip edge | Required |
| Minimum drip edge size | 1 x 2 |
| Requires rake / gable metal edging | Required |
| Self adhering underlayment (ice and water shield) | Ice barrier required at eaves per the IRC |
| Underlayment required 2:12 up to 4:12 | Two layers of underlayment |
| Underlayment required 4:12 and above | One layer of underlayment |
| Type of valleys allowed | Both |
| Kick-out required on step flashing | Required where the roof meets a wall |
| Requires ridge cap | Required, installed to manufacturer specifications |
| Requires ventilation to meet code | Yes, per code |
| Blower door test when increasing ventilation to code | Required on new construction under the 2021 IECC |
| Requires soffit / eave vents | Required per IRC attic ventilation provisions |
Last checked September 2, 2026. This reflects published sources at that date, not an official ruling. Code adoptions change, so confirm with the Englewood building department before you pull a permit.
What Englewood requires, in plain language
Englewood builds to the 2021 IBC and 2021 IRC. That edition, not the newest code published nationally, is the rulebook an inspector in Arapahoe County holds your roof to. Energy work on the same permit follows the 2021 IECC.
Layer limit in Englewood: One layer. This is the line item that moves a bid the most. If your existing roof is already at the limit, the deck gets stripped before new material goes down, and the labor plus dump fees belong in the written price. Flat roof sections are capped at One layer.
Wind is what Englewood tests shingles against. Rating is proven under D-3161.
Underlayment and edge metal are where roofs fail inspection. Ice and water shield: Ice barrier required at eaves per the IRC. On 2:12 to 4:12 slopes: Two layers of underlayment. On 4:12 and steeper: One layer of underlayment. Drip edge: Required. Minimum drip edge size 1 x 2.
Englewood publishes its adopted codes and local amendments on the Building Code Amendments page. Local amendments can change roofing details, so read them alongside the base code.
Installation details above come from our building department field survey for Englewood, last updated 9-23-2018. Code editions and contacts are refreshed from the department directly. Always confirm the details on your permit before work starts, since departments amend requirements on their own schedule.

Sources
- https://www.englewoodco.gov/government/city-departments/building-division
- https://www.englewoodco.gov/government/city-departments/building-division/building-code-amendments
These links go straight to the jurisdiction, so you always have the real-time source. Adoptions and amendments change on their schedule, not ours. Always confirm before permitting.
Last checked September 2, 2026. This is our best read of published sources, not an official ruling. Confirm with the Englewood building department before you pull a permit.