Firestone Roofing Codes: Permits, Inspections, and Requirements
Adopted building and energy codes, permit rules, and roofing requirements for Firestone, Weld County. Rows below reflect our reading of the jurisdiction's own published sources, linked at the bottom of the page.
Firestone roofing code requirements
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Class C
- What this jurisdiction requires
- Class C
- What this jurisdiction requires
- Class C
- What this jurisdiction requires
- 90 MPH sustained/110 MPH 3 second gusts
- What this jurisdiction requires
- Must meet manufacturer rating for 90 MPH
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- No
- What this jurisdiction requires
- No
- What this jurisdiction requires
- No
- What this jurisdiction requires
- One overlay allowed
- What this jurisdiction requires
- One overlay allowed
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Any gap at all
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- 1×2
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- No
- What this jurisdiction requires
- Double underlayment required
- What this jurisdiction requires
- 15 pound
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- Both
- What this jurisdiction requires
- 90 pound
- What this jurisdiction requires
- 90 pound under metal
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- 24" or greater width
- What this jurisdiction requires
- No
- What this jurisdiction requires
- Yes
- What this jurisdiction requires
- No
- What this jurisdiction requires
- No
| Requirement | What this jurisdiction requires |
|---|---|
| Building permit required | Yes |
| Roof system fire rating (residential) | Class C |
| Roof system fire rating (commercial) | Class C |
| Roof system fire rating (multi-family) | Class C |
| Minimum wind speed rating for asphalt shingles | 90 MPH sustained/110 MPH 3 second gusts |
| Requires a manufacturer wind warranty | Must meet manufacturer rating for 90 MPH |
| Requires wind nailing | Yes |
| Inspectors carry ladders for the final | No |
| Requires midroof (in progress) inspection | No |
| Requires a sheathing / decking inspection | No |
| Maximum layers of asphalt shingles permitted | One overlay allowed |
| Maximum layers of flat roof material permitted | One overlay allowed |
| Requires solid sheeting over spaced decking | Yes |
| Sheeting gap requirement | Any gap at all |
| Requires drip edge | Yes |
| Minimum drip edge size | 1×2 |
| Requires rake / gable metal edging | Yes |
| Self adhering underlayment (ice and water shield) | No |
| Underlayment required 2:12 up to 4:12 | Double underlayment required |
| Underlayment required 4:12 and above | 15 pound |
| Rolled roofing allowed on low slope over living space | Yes |
| Type of valleys allowed | Both |
| Valley material required for closed valleys | 90 pound |
| Valley material required for open valleys | 90 pound under metal |
| Kick-out required on step flashing | Yes |
| Chimney cricket requirement | 24" or greater width |
| Minimum curb height requirement | No |
| Requires ridge cap | Yes |
| Blower door test when increasing ventilation to code | No |
| Requires soffit / eave vents | No |
Last checked September 2, 2026. This reflects published sources at that date, not an official ruling. Code adoptions change, so confirm with the Firestone building department before you pull a permit.
What Firestone requires, in plain language
Layer limit in Firestone: One overlay allowed. This is the line item that moves a bid the most. If your existing roof is already at the limit, the deck gets stripped before new material goes down, and the labor plus dump fees belong in the written price. Flat roof sections are capped at One overlay allowed.
Wind is what Firestone tests shingles against. Shingles need a 90 MPH sustained/110 MPH 3 second gusts rating. Wind nailing: Yes. Manufacturer wind warranty: Must meet manufacturer rating for 90 MPH.
Underlayment and edge metal are where roofs fail inspection. Ice and water shield: No. On 2:12 to 4:12 slopes: Double underlayment required. On 4:12 and steeper: 15 pound. Drip edge: Yes. Minimum drip edge size 1×2.
How Firestone inspects the job. Midroof inspection: No. Sheathing or decking inspection: No. Inspectors carrying ladders for the final: No. Permit: Yes.
Firestone adopts the International Building Code by reference through Municipal Code Chapter 15.04, most recently amended in full in 2023. The town does not publish an edition table online, so call the building department for the edition in force.
Installation details above come from our building department field survey for Firestone, last updated 8/22/18. Code editions and contacts are refreshed from the department directly. Always confirm the details on your permit before work starts, since departments amend requirements on their own schedule.

Sources
- https://www.firestoneco.gov/425/Building-Permits-Fees
- https://library.municode.com/co/firestone/codes/municipal_code
These links go straight to the jurisdiction, so you always have the real-time source. Adoptions and amendments change on their schedule, not ours. Always confirm before permitting.
Keep going
Nearby jurisdictions
Last checked September 2, 2026. This is our best read of published sources, not an official ruling. Confirm with the Firestone building department before you pull a permit.