Roofing work in Centennial, Colorado by Peak to Peak Roofing
All Colorado roofing codes

Centennial Roofing Codes: Permits, Inspections, and Requirements

Adopted building and energy codes, permit rules, and roofing requirements for Centennial, Arapahoe and Douglas Counties. Rows below reflect our reading of the jurisdiction's own published sources, linked at the bottom of the page.

Last checked Compiled from published Arapahoe and Douglas Counties and city pages

Centennial roofing code requirements

Centennial roofing code reference
Current building code
What this jurisdiction requires
2021 IBC and 2021 IRC
Current energy code
What this jurisdiction requires
2018 IECC
Building permit required
What this jurisdiction requires
Yes
Roof system fire rating (residential)
What this jurisdiction requires
Class A
Minimum wind speed rating for asphalt shingles
What this jurisdiction requires
90 MPH Sustained/110 MPH 3-second gusts
Requires wind nailing
What this jurisdiction requires
Yes
Inspectors carry ladders for the final
What this jurisdiction requires
Yes, with one story access
Requires midroof (in progress) inspection
What this jurisdiction requires
Yes, inspection required at 25% to 75% shingled for concrete, tile, and shake shingle, metal, and flat roofs.
Requires a sheathing / decking inspection
What this jurisdiction requires
No
Maximum layers of asphalt shingles permitted
What this jurisdiction requires
One layer
Maximum layers of flat roof material permitted
What this jurisdiction requires
Single layer only
Requires solid sheeting over spaced decking
What this jurisdiction requires
Yes
Sheeting gap requirement
What this jurisdiction requires
½ inch gap
Requires drip edge
What this jurisdiction requires
Required
Requires rake / gable metal edging
What this jurisdiction requires
Required
Self adhering underlayment (ice and water shield)
What this jurisdiction requires
Ice barrier required at eaves per the IRC
Underlayment required 2:12 up to 4:12
What this jurisdiction requires
Two layers of underlayment
Underlayment required 4:12 and above
What this jurisdiction requires
One layer of underlayment
Rolled roofing allowed on low slope over living space
What this jurisdiction requires
Yes
Type of valleys allowed
What this jurisdiction requires
Both
Valley material required for closed valleys
What this jurisdiction requires
90 pound
Valley material required for open valleys
What this jurisdiction requires
Ice and water under metal
Kick-out required on step flashing
What this jurisdiction requires
Required where the roof meets a wall
Chimney cricket requirement
What this jurisdiction requires
30 inch or greater width
Minimum curb height requirement
What this jurisdiction requires
No
Requires ridge cap
What this jurisdiction requires
Required, installed to manufacturer specifications
Requires ventilation to meet code
What this jurisdiction requires
Yes
Blower door test when increasing ventilation to code
What this jurisdiction requires
Required on new construction under the 2018 IECC
Requires soffit / eave vents
What this jurisdiction requires
Required per IRC attic ventilation provisions

Last checked September 2, 2026. This reflects published sources at that date, not an official ruling. Code adoptions change, so confirm with the Centennial building department before you pull a permit.

What Centennial requires, in plain language

Centennial builds to the 2021 IBC and 2021 IRC. That edition, not the newest code published nationally, is the rulebook an inspector in Arapahoe and Douglas Counties holds your roof to. Energy work on the same permit follows the 2018 IECC.

Layer limit in Centennial: One layer. This is the line item that moves a bid the most. If your existing roof is already at the limit, the deck gets stripped before new material goes down, and the labor plus dump fees belong in the written price. Flat roof sections are capped at Single layer only.

Wind is what Centennial tests shingles against. Shingles need a 90 MPH Sustained/110 MPH 3-second gusts rating. Wind nailing: Yes.

Underlayment and edge metal are where roofs fail inspection. Ice and water shield: Ice barrier required at eaves per the IRC. On 2:12 to 4:12 slopes: Two layers of underlayment. On 4:12 and steeper: One layer of underlayment. Drip edge: Required.

Centennial Ordinance 2023-O-06 adopted the 2021 IBC, IRC, IMC, IFGC, IPC and IFC, and kept the energy code on the 2018 IECC.

Installation details above come from our building department field survey for Centennial, last updated 8/22/18. Code editions and contacts are refreshed from the department directly. Always confirm the details on your permit before work starts, since departments amend requirements on their own schedule.

Code compliant roof installation near Centennial, Colorado

Sources

These links go straight to the jurisdiction, so you always have the real-time source. Adoptions and amendments change on their schedule, not ours. Always confirm before permitting.

Last checked September 2, 2026. This is our best read of published sources, not an official ruling. Confirm with the Centennial building department before you pull a permit.